Temperature and Pressure Effects on Transmitted flux

and Build up Factor in cylindrical duct

 

Effet de température et de pression sur le flux  transmis

et le facteur  d’accumulation dans un canal cylindrique

 

Z. Faik Ouahab, A. Oubaiddou, J.Ghassoun, A. Jehouani*

EPRA, Département de Physique, Faculté de Sciences Semlalia, BP. 2390, Université Cadi Ayyad, Marrakech, Maroc.

* Corresponding author. E-mail: jehouani@ucam.ac.ma

Received: 11 December 2007; revised version accepted: 28 July 2008

 

Abstract

     This study deals with the effects               of pressure and temperature in manufacturing wall duct on the neutron transmission probability through duct. A Monte Carlo program is developed to simulate the neutron trajectories through the duct. The neutron statistical weight is corrected after each interaction by using appropriate factors .The MCNP-5C code is used to validate our program. We determined the neutron fluxes and spectra at the duct exit.

 

Keywords: Monte Carlo; Neutron; Duct; Flux; Spectra; Building Factor.

      

Résumé

     Cette étude traite l’effet de la température et de la pression de fabrication des parois en fer d’un canal sur la contribution des neutrons à la sortie d’un canal cylindrique droit et vide. Un programme basé sur la méthode Monte Carlo permet de simuler les parcours du neutron, les points d’interaction et la direction après chaque diffusion. Le poids statistique du neutron initial est corrigé par un facteur approprié à chaque événement. Les résultats obtenus sont validés par le code MCNP-5C. Nous avons déterminé  le flux neutronique, énergétique et le spectre neutronique des neutrons à la sortie du canal ainsi que le facteur d’accumulation.

 

Mots clés: Monte Carlo; Neutron; Canal; Facteur d’accumulation; Flux transmis.