Analyse exergétique d’une unité

de concentration de l’acide phosphorique

Z. Meddeb1*, M. H. Gazzah2, M. R. Jeday1

1*Laboratoire d’Energétique et d’Ingénierie, Ecole Nationale d’Ingénieurs de Gabès, Route de Medenine, 6029 Gabès, Tunisie

2Laboratoire d’Etudes des Systèmes Thermiques et Energétiques, Ecole Nationale d’Ingénieurs de Monastir, Route de Kairouan 5019 Monastir, Tunisie

* Corresponding author. E-mail : Zina.Meddeb@ipeigb.rnu.tn

Received : 19 April 2002; revised version accepted : 10 June 2002

Abstract

This paper is devoted to the evaluation of energy performances through the exergy analysis of a phosphorique acid production unit belauging to the D.A.P factory of the Tunisian Chemical Group. The obtained results allow to calculate exergy losses and localize the areas that are most responsible of energy degradation. they show that the major part of exergy is degraded to the level of the in the heat exchanger (48%) and in the reboiler (49%). These two equipments possess therefore the highest potential of improvement.

Keywords : Entropy ; Exergy ; Concentration.

Résumé 

Cet article est consacrée à l’analyse des performances énergétiques d’une unité de concentration de l’acide phosphorique de l’usine D.A.P du Groupe Chimique Tunisien en s’appuyant sur la méthode de l’analyse exergétique. Les résultats obtenus permettent de calculer les pertes d’exergie et de localiser les zones de l’unité les plus dégradantes d’énergie. Les résultats des calcules montrent que la majeure partie de l’exergie est dégradée au niveau de l’échangeur (48%) et au niveau de la chambre flash (49%). Ces deux équipements possèdent donc le grand potentiel d’amélioration.

Mots clefs : Entropie ; Exergie ; Concentration.

© 2015